ID | Name | Description |
---|---|---|
5.1 | Device Configuration Service | The FN VictoR SDK shall provide developers with a multi-platform, multi-protocol Device Configuration Service that allows for reading and writing of device configuration parameters to and from an FN Victor device over a common interface. |
5.2 | Read Optical Path Video Parameter | The Device Configuration Service shall provide the ability to get the optical path video parameter from an FN VictoR device as a value indicating short-range, long-range, or auto-range. |
5.3 | Write Optical Path Video Parameter | The Device Configuration Service shall provide the ability to set the optical path video parameter (optical path field) of an FN VictoR device to a value indicating short-range, long-range, or auto-range. |
5.4 | Read Bluetooth Link General System Parameter | The Device Configuration Service shall provide the ability to get the Bluetooth link general system parameter from an FN VictoR device as a value indicating disabled or enabled. |
5.5 | Write Bluetooth Link General System Parameter | The Device Configuration Service shall provide the ability to set the Bluetooth link general system parameter of an FN VictoR device to a value indicating disable or enable. |
5.6 | Read System LED General System Parameter | The Device Configuration Service shall provide the ability to get the system LED general system parameter from an FN VictoR device as a value indicating disabled or enabled. |
5.7 | Write System LED General System Parameter | The Device Configuration Service shall provide the ability to set the system LED general system parameter of an FN VictoR device to a value indicating disable or enable. |
5.8 | Read Buzzer General System Parameter | The Device Configuration Service shall provide the ability to get the buzzer general system parameter from an FN VictoR device as as a value indicating disabled or enabled. |
5.9 | Write Buzzer General System Parameter | The Device Configuration Service shall provide the ability to set the buzzer general system parameter of an FN VictoR device to a value indicating disable or enable. |
5.10 | Read System Time | The Device Configuration Service shall provide the ability to get the system time from an FN VictoR device as a Unix Epoch formatted timestamp. |
5.11 | Write System Time | The Device Configuration Service shall provide the ability to set the system time of an FN VictoR device to a Unix Epoch formatted timestamp. |
5.12 | Read VictoR Mounting Orientation Training Parameter | The Device Configuration Service shall provide the ability to get the Picatinny rail mounting position from an FN VictoR device as a value indicating a position defined with respect to the muzzle of either above (12 o’clock), below (6 o’clock), left (9 o’clock), or right (3 o’clock). |
5.13 | Write VictoR Mounting Orientation Training Parameter | The Device Configuration Service shall provide the ability to set the Picatinny rail mounting position of an FN VictoR device to a value indicating a position defined with respect to the muzzle of either above (12 o’clock), below (6 o’clock), left (9 o’clock), or right (3 o’clock). |
5.14 | Read Aimpoint Offsets Training Parameter | The Device Configuration Service shall provide the ability to get the aimpoint offsets training parameter from an FN VictoR device as a column offset +/- the maximum image width and a row offset +/- the maximum image height. |
5.1315 | Write Aimpoint Offsets Training Parameter | The Device Configuration Service shall provide the ability to set the aimpoint offsets training parameter of an FN VictoR device to a column offset +/- the maximum image width and a row offset +/- the maximum image height. |
5.1416 | Read Shot Rejection Angle Training Parameter | The Device Configuration Service shall provide the ability to get the shot rejection angle training parameter from an FN VictoR device as an angle between 0 and 90 degrees. |
5.1517 | Write Shot Rejection Angle Training Parameter | The Device Configuration Service shall provide the ability to set the shot rejection angle training parameter of an FN VictoR device to an angle between 0 and 90 degrees. |
5.1618 | Read System Power Command | The Device Configuration Service shall provide the ability to get whether the last system power command sent to an FN VictoR device was to power off or to reboot system. |
5.1719 | Write System Power Command | The Device Configuration Service shall provide the ability to send a system power command to an FN VictoR device indicating it should power off or reboot system. |
5.1820 | Read Vision System Command | The Device Configuration Service shall provide the ability to get whether the last vision system command sent to an FN VictoR device was a “target recognition system control” command or a “get a shot clip” command. |
5.1921 | Write Vision System Command | The Device Configuration Service shall provide the ability to send a vision system command to an FN VictoR device as either a “target recognition system control” command or a “get a shot clip” command. |
5.2022 | Read Target Recognition System Control Vision System Command Data | The Device Configuration Service shall provide the ability to get the last vision system command data sent to an FN VictoR device as either a value indicating “interface engine control stop” or “interface engine control start” if the command was a “target recognition system control” command. |
5.2123 | Read Shot Clip Vision System Command Data | The Device Configuration Service shall provide the ability to get the last vision system command data sent to an FN VictoR device as a value indicating the shot identifier if the command was a “get a shot clip” command. |
5.2224 | Write Target Recognition System Vision System Command Data | The Device Configuration Service shall provide the ability to set the vision system command data sent to an FN VictoR device as either a value indicating “interface engine control stop” or “interface engine control start” if the command was a “target recognition system control” command. |
5.2325 | Write Shot Clip Vision System Command Data | The Device Configuration Service shall provide the ability to set the vision system command data sent to an FN VictoR device as a value indicating the shot identifier if the command was a “get a shot clip” command. |
5.2426 | Read Trigger Threshold Value Trigger Detection Parameter | The Device Configuration Service shall provide the ability to get the trigger threshold value trigger detection parameter from an FN VictoR device as a value between 0 and Tmax. |
5.2527 | Write Trigger Threshold Value Trigger Detection Parameter | The Device Configuration Service shall provide the ability to set the trigger threshold value trigger detection parameter of an FN VictoR device to a value between 0 and Tmax. |
5.2628 | Read Maximum Trigger Threshold Value Trigger Detection Parameter | The Device Configuration Service shall provide the ability to get the maximum trigger threshold value (Tmax) trigger detection parameter from an FN VictoR device as a value between 0 and 65535. |
5.2729 | Write Maximum Trigger Threshold Value Trigger Detection Parameter | The Device Configuration Service shall provide the ability to set the maximum trigger threshold value (Tmax) trigger detection parameter of an FN VictoR device to a value between 0 and 65535. |
5.2830 | Read Trigger Impact Window Trigger Detection Parameter | The Device Configuration Service shall provide the ability to get the trigger impact window trigger detection parameter from an FN VictoR device as a value between 1 and 99 milliseconds. |
5.2931 | Write Trigger Impact Window Trigger Detection Parameter | The Device Configuration Service shall provide the ability to set the trigger impact window trigger detection parameter of an FN VictoR device to a value between 1 and 99 milliseconds. |
5.3032 | Read Post-Trigger Impact Window Trigger Detection Parameter | The Device Configuration Service shall provide the ability to get the post-trigger impact window trigger detection parameter from an FN VictoR device as a value between 0 and 65535 milliseconds. |
5.3133 | Write Post-Trigger Impact Window Trigger Detection Parameter | The Device Configuration Service shall provide the ability to set the post-trigger impact window trigger detection parameter of an FN VictoR device to a value between 0 and 65535 milliseconds. |
5.3234 | Read Detection Threshold Target Recognition System Parameter | The Device Configuration Service shall provide the ability to get the detection threshold target recognition system parameter from an FN VictoR device as a percentage between 0 and 100. |
5.3335 | Write Detection Threshold Target Recognition System Parameter | The Device Configuration Service shall provide the ability to set the detection threshold target recognition system parameter of an FN VictoR device to a percentage between 0 and 100. |
...