Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

ID

Name

Description

5.1

Device Configuration Service

The FN VictoR SDK shall provide developers with a multi-platform, multi-protocol Device Configuration Service that allows for reading and writing of device configuration parameters to and from an FN Victor device over a common interface.

5.2

Read Optical Path Video Parameter

The Device Configuration Service shall provide the ability to get the optical path video parameter from an FN VictoR device as a value indicating short-range, long-range, or auto-range.

5.3

Write Optical Path Video Parameter

The Device Configuration Service shall provide the ability to set the optical path video parameter (optical path field) of an FN VictoR device to a value indicating short-range, long-range, or auto-range.

5.4

Read Bluetooth Link General System Parameter

The Device Configuration Service shall provide the ability to get the Bluetooth link general system parameter from an FN VictoR device as a value indicating disabled or enabled.

5.5

Write Bluetooth Link General System Parameter

The Device Configuration Service shall provide the ability to set the Bluetooth link general system parameter of an FN VictoR device to a value indicating disable or enable.

5.6

Read System LED General System Parameter

The Device Configuration Service shall provide the ability to get the system LED general system parameter from an FN VictoR device as a value indicating disabled or enabled.

5.7

Write System LED General System Parameter

The Device Configuration Service shall provide the ability to set the system LED general system parameter of an FN VictoR device to a value indicating disable or enable.

5.8

Read Buzzer General System Parameter

The Device Configuration Service shall provide the ability to get the buzzer general system parameter from an FN VictoR device as as a value indicating disabled or enabled.

5.9

Write Buzzer General System Parameter

The Device Configuration Service shall provide the ability to set the buzzer general system parameter of an FN VictoR device to a value indicating disable or enable.

5.10

Read System Time

The Device Configuration Service shall provide the ability to get the system time from an FN VictoR device as a Unix Epoch formatted timestamp.

5.11

Write System Time

The Device Configuration Service shall provide the ability to set the system time of an FN VictoR device to a Unix Epoch formatted timestamp.

5.12

Read VictoR Mounting Orientation Training Parameter

The Device Configuration Service shall provide the ability to get the Picatinny rail mounting position from an FN VictoR device as a value indicating a position defined with respect to the muzzle of either above (12 o’clock), below (6 o’clock), left (9 o’clock), or right (3 o’clock).

5.13

Write VictoR Mounting Orientation Training Parameter

The Device Configuration Service shall provide the ability to set the Picatinny rail mounting position of an FN VictoR device to a value indicating a position defined with respect to the muzzle of either above (12 o’clock), below (6 o’clock), left (9 o’clock), or right (3 o’clock).

5.14

Read Aimpoint Offsets Training Parameter

The Device Configuration Service shall provide the ability to get the aimpoint offsets training parameter from an FN VictoR device as a column offset +/- the maximum image width and a row offset +/- the maximum image height.

5.1315

Write Aimpoint Offsets Training Parameter

The Device Configuration Service shall provide the ability to set the aimpoint offsets training parameter of an FN VictoR device to a column offset +/- the maximum image width and a row offset +/- the maximum image height.

5.1416

Read Shot Rejection Angle Training Parameter

The Device Configuration Service shall provide the ability to get the shot rejection angle training parameter from an FN VictoR device as an angle between 0 and 90 degrees.

5.1517

Write Shot Rejection Angle Training Parameter

The Device Configuration Service shall provide the ability to set the shot rejection angle training parameter of an FN VictoR device to an angle between 0 and 90 degrees.

5.1618

Read System Power Command

The Device Configuration Service shall provide the ability to get whether the last system power command sent to an FN VictoR device was to power off or to reboot system.

5.1719

Write System Power Command

The Device Configuration Service shall provide the ability to send a system power command to an FN VictoR device indicating it should power off or reboot system.

5.1820

Read Vision System Command

The Device Configuration Service shall provide the ability to get whether the last vision system command sent to an FN VictoR device was a “target recognition system control” command or a “get a shot clip” command.

5.1921

Write Vision System Command

The Device Configuration Service shall provide the ability to send a vision system command to an FN VictoR device as either a “target recognition system control” command or a “get a shot clip” command.

5.2022

Read Target Recognition System Control Vision System Command Data

The Device Configuration Service shall provide the ability to get the last vision system command data sent to an FN VictoR device as either a value indicating “interface engine control stop” or “interface engine control start” if the command was a “target recognition system control” command.

5.2123

Read Shot Clip Vision System Command Data

The Device Configuration Service shall provide the ability to get the last vision system command data sent to an FN VictoR device as a value indicating the shot identifier if the command was a “get a shot clip” command.

5.2224

Write Target Recognition System Vision System Command Data

The Device Configuration Service shall provide the ability to set the vision system command data sent to an FN VictoR device as either a value indicating “interface engine control stop” or “interface engine control start” if the command was a “target recognition system control” command.

5.2325

Write Shot Clip Vision System Command Data

The Device Configuration Service shall provide the ability to set the vision system command data sent to an FN VictoR device as a value indicating the shot identifier if the command was a “get a shot clip” command.

5.2426

Read Trigger Threshold Value Trigger Detection Parameter

The Device Configuration Service shall provide the ability to get the trigger threshold value trigger detection parameter from an FN VictoR device as a value between 0 and Tmax.

5.2527

Write Trigger Threshold Value Trigger Detection Parameter

The Device Configuration Service shall provide the ability to set the trigger threshold value trigger detection parameter of an FN VictoR device to a value between 0 and Tmax.

5.2628

Read Maximum Trigger Threshold Value Trigger Detection Parameter

The Device Configuration Service shall provide the ability to get the maximum trigger threshold value (Tmax) trigger detection parameter from an FN VictoR device as a value between 0 and 65535.

5.2729

Write Maximum Trigger Threshold Value Trigger Detection Parameter

The Device Configuration Service shall provide the ability to set the maximum trigger threshold value (Tmax) trigger detection parameter of an FN VictoR device to a value between 0 and 65535.

5.2830

Read Trigger Impact Window Trigger Detection Parameter

The Device Configuration Service shall provide the ability to get the trigger impact window trigger detection parameter from an FN VictoR device as a value between 1 and 99 milliseconds.

5.2931

Write Trigger Impact Window Trigger Detection Parameter

The Device Configuration Service shall provide the ability to set the trigger impact window trigger detection parameter of an FN VictoR device to a value between 1 and 99 milliseconds.

5.3032

Read Post-Trigger Impact Window Trigger Detection Parameter

The Device Configuration Service shall provide the ability to get the post-trigger impact window trigger detection parameter from an FN VictoR device as a value between 0 and 65535 milliseconds.

5.3133

Write Post-Trigger Impact Window Trigger Detection Parameter

The Device Configuration Service shall provide the ability to set the post-trigger impact window trigger detection parameter of an FN VictoR device to a value between 0 and 65535 milliseconds.

5.3234

Read Detection Threshold Target Recognition System Parameter

The Device Configuration Service shall provide the ability to get the detection threshold target recognition system parameter from an FN VictoR device as a percentage between 0 and 100.

5.3335

Write Detection Threshold Target Recognition System Parameter

The Device Configuration Service shall provide the ability to set the detection threshold target recognition system parameter of an FN VictoR device to a percentage between 0 and 100.

...