Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In SOW but Missing from ICD

  • Set device name

    • Not currently supported

    • FN/Jabil to discuss further

    • Awaiting follow up from FN/Jabil on if/when it will be supported

  • Set default username

    • Implemented as “Shooter Name Training Parameter” but stricken from ICD

    • Not currently supported

    • Awaiting follow up from Jabil on if/when it will be supported

    • Supported as of ICD Rev F with current firmware

  • Set computer vision model

    • Awaiting follow up from Jabil on how to read this from the device

  • Set computer vision application

    • Not currently supported

    • Awaiting follow up from Jabil on if/when it will be supported

  • Set mounting orientation

    • Is in fact “VictoR Mounting Orientation Training Parameter Structure”

    • Is stricken from the ICD, but it is implemented with the caveat that it is unstable

    • Awaiting follow up from Jabil on when it will be stabilized

    • Supported as of ICD Rev F with current firmware

    • Requires a device reboot to take effect

  • Enable/Disable physical buttons

    • Not currently supported

    • Awaiting follow up from Jabil on if/when it will be supported

  • Set sleep mode timer

    • Implemented as “Minimum Inactivity Interval General System Parameter” but stricken from ICD

    • Not currently supported

    • Awaiting follow up from Jabil on if/when it will be supported

    • Supported as of ICD Rev F with current firmware

ICD Clarification: Device Information Service

  • Notify Battery Level

    • Would like to know/verify what percentages trigger this

    • Awaiting follow up from Jabil with percentages

    • Appears to notify approximately once per second regardless of percentage

  • Trained NN Model File

    • There is a read but no write

    • Awaiting follow up from Jabil on how to change this

  • Last Holster Draw Information

    • Listed in ICD, but reported as not currently supported by Jabil

    • Awaiting follow up from Jabil on if/when it will be supported

...

  • System Power Command

    • ICD says this is read/write but Jabil (Scott) is unsure if read support is a typo

    • If read is supported, need clarification on what exactly that means - read back of last command issued?

    • Awaiting further clarification from Jabil

    • Supported as of ICD Rev F with current firmware

    • Always reads as 0

  • Trigger Detection Parameters

    • Deprecated in ICD Rev G and replaced with Threshold-Based Trigger Detection Parameters

ICD Clarification: Aimpoint Data Service

...

  • File Write/List/Info/Delete Command Classes

    • Stricken from ICD

    • Jabil says it will be supported

    • Need an estimate on completion/availability

    • Supported as of ICD Rev F with current firmware

ICD Clarification: USB Interface

...