FN Controller - At Risk MVP

1.2.4.          Oblique Processing (MVP_011 - MVP_012)

1.2.4.1.          Fix shot trace orientation when firing at oblique angles

WBA

MVP

CATEGORY

FEATURE

 

WBA

MVP

CATEGORY

FEATURE

 

1.2.4

MVP_011

Oblique Processing

As a operator I expect the software set the rendering of the target always flat including the process of the trace even when I shoot with a oblique angle so that the results are easy to see.

(Scoring and predicted point of impact shall be consistent with target orientation)

There are multiple cases in which a bounding box could have a smaller width or height, and sometimes this happens when a target is slightly off the edge of the screen but the vision system still recognizes part of it. In those cases, you will have a partial bounding box. We don't have a way to differentiate this from a smaller bounding box due to an oblique angle. Furthermore, the bounding box for an oblique angle does not come with any metric for obliqueness from the firmware, and without direct access to pixel data, we don't know the angle of the target in order to adjust aim trace scaling across the target.

1.2.4

MVP 012

Oblique Processing/ Image Download

 As a operator I can download the image of each shot separately so that I can visualize the context and angle of target engagement.

 

1.2.5.          IMU Data (MVP_013)

1.2.5.1.          Use prediction point as start point then use IMU data for shot trace rendering and filtering for better resolution

WBA

MVP

CATEGORY

FEATURE

 

WBA

MVP

CATEGORY

FEATURE

 

1.2.5

MVP_013

IMU data

IMU data must be used in place of using predicted point of impact (extracted from Aimpoint service) for drawing the trace. A filter needs to be applied to avoid unwanted spurious movement of the gun.

Not supported by firmware.

 

1.2.9.          Previous Session (MVP_020)

1.2.9.1.          Download previous sessions from device

WBA

MVP

CATEGORY

FEATURE

 

WBA

MVP

CATEGORY

FEATURE

 

1.2.9

MVP_020

Previous session

As a user, I can download a previously completed session completed in "Standalone mode" so that I can see and analyze my session on a controller device.

Would be difficult or impossible to download using Bluetooth. Work-around is to connect and download using WinSCP.

 

1.2.13.          Moving Target (MVP_036 - MVP_037)

1.2.13.1.           Display distance, speed, and direction of target, data is received from VictoR WASP
1.2.13.2.           Display predicted point of impact to accommodate moving target

WBA

MVP

CATEGORY

FEATURE

 

WBA

MVP

CATEGORY

FEATURE

 

1.2.13

MVP 036

Moving target

The system shall display the distance, speed, and direction of a moving pretrained target [display vector graphic on direction of movement, and speed]

Moving target has been implemented but we have not been able to do a proper test. The system lacks proper documentation on how to create conditions for a moving target test and on top of that, the lack of functional devices makes setting up a test impossible. We are reliant on FN to test this for us and as of yet, they have not been able to test.

1.2.13

MVP 037

Moving target

The system shall augment the display of the predicted point of impact to accommodate for a pretrained moving target